Sensor technologies in biomedical engineering (SensorTechBME) research group

Head of the research group
Overview
The main research field of the SensorTechBME team is to develop flexible and novel sensor technologies and algorithms in biomedical engineering applications: ‚ To estimate dialysis adequacy and quality securing end stage renal disease (ESRD) patients’ care quality. The research is exploring spectrophotometrical and spectrofluorimetrical characteristics-signatures of the biofluids and performing various signal processing and analysis on those signals. ‚ To develop beyond the state-of-the-art applications incorporated into a smart wearable multi-sensor fusion system for generating valuable data about the workers’ location, locomotion, physical activity, energy consumption and physiological status; ‚ For speech-to-text usage in healthcare and industry.
Keyword
algorithms
sensor fusion
biofluid optics
uremic toxins
dialysis
on-line monitoring
spectrophotometry
spectrofluorimetry
smart work wear
physical activity monitoring
energy consumption
fatigue monitoring
automatic speech recognition
speech-to-text applications
Important results
In 2025, for the first time, a clinical research study conducted and published by the research group (Paats et al 2025), has shown that the concentration of the biomarker, C-mannosyltryptophan (CMW), in the blood of patients with chronic kidney disease (CKD) is several times higher than that of healthyindividuals. The technical and methodological innovation is reflected in the first-ever determination of CMW concentration in the dialysate used by spectrophotometric analysis. Its implementation would be a major change in current clinical practice and would help ensure more adequate assessment oftreatment quality and better survival and quality of life for the patient. The study creates favorable ground for the wider use of the optical monitoring method of uremic residues developed by TalTech scientists in clinical practice. In addition to the novel, CMW-based, methodological approach, it is also important for the patient that the optical sensor uses the effluent dialysate fluid for measurement and does not require blood sampling. This saves blood for patients on renal replacement therapy with already impaired hematopoiesis. The proposed optical methodology significantly contributes to the move towards more environmentally friendly dialysis treatment, since when measuring concentrations with an optical sensor, there is no need to use blood sample tubes, costs for laboratory analyses are eliminated, and less waste is generated.